PIN WORKER UNIT | TYP PWU
The pin worker unit is mainly used for intensive treatment of margarine and edible fat products, in order to achieve a proper crystallisation and right texture during the production process. Depending on product and desired consistency the pin worker unit can either be placed between the cooling steps or at the end of the cooling process.
The RONO pin worker unit is based on proven technique. Our further development enhanced the pin worker to meet best flexibility, highest standard of hygiene, very long life expectancy and easy maintenance in daily operation. The RONO pin worker unit offers highest flexibility to the production process and allows to work with a wide diversity of fat products. Adjustments to the level and intensity of treatment can be made by adjustment of the pin rotor speed.
Production capacity and volume of the pin worker unit offers a variable duration of kneading. Product crystallisation can be influenced by the choice of high or lower pressure production.
Types & Variations
Cylinder sizes
Ø 250 mm, 336 mm | Different lengths available
Volumes
The pin worker unit is available in various sizes and with different volumes: 25 ℓ, 50 ℓ, 100 ℓ, 120 ℓ und 180 ℓ
Modular Design
The pin worker unit can be build as stand-alone version or together with further pin worker units, mounted on a solid baseplate. Alternatively the PWU can be mounted on top of the RONOTHOR.
Working pressure range
Up to 120 bar
BENEFITS
TECHNICAL DATA
PWU size in litre [ℓ] | 25 | 50 | 100 | 120 | 180 |
---|---|---|---|---|---|
Gear Motor [kW] | 5,5 | 7,5 | 11 | 15 | 18,5 |
RPM Rotor [1/min, 50 Hz] | 50 – 400 | 50 – 350 | 50 – 400 | 50 – 350 | 50 – 350 |
Frequency Converter [kW] | 5,5 | 7,5 | 11 | 15 | 18,5 |
Cylinder Volume in litre [ℓ] | 25 | 50 | 100 | 120 | 180 |
Design pressure [bar] | 120 | 120 | 120 | 120 | 120 |
Temp. Sensor PT100 [pc.] | 1 | 1 | 1 | 1 | 1 |
Recommended Water Temperation Unit
Water Heater Volume in litre [ℓ] | 60 | 60 | 60 | 60 | 60 |
---|---|---|---|---|---|
Heating element [kW] | 9 | 9 | 9 | 9 | 9 |
Water Circulation pump [kW] | 0,37 | 0,37 | 0,37 | 0,37 | 0,37 |